SIDNs
S00055Positionpolarityparameters
Theparametercanbeusedtoinvertthepolarityofpositiondata.
Attributes
Name Value
Format Binary
Datalength 16
Decimalpoint 0
Minvalue 0
Maxvalue 0x000F
Defaultvalue
Unit
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
relatedtointerfacerevision
Thepolaritiesareswitchedattheinputandoutputoftheclosedcontrolloopandthereforedonotaffectthe
closedcontrolloopsinthedrive.Themotorshaftrotatesinaclockwisedirection(viewedfromthefrontonto
themotorshaft),ifthereisapositivepositioncommandvaluedifferenceandthereisnoinversion.
Bitpattern:
Bit Meaning
0 Positioncommandvalue
Positioncommandvalue
0=notinverted
1=inverted
1 Additivepositioncommandvalue
Additivepositioncommandvalue
0=notinverted
1=inverted
2 Positionfeedbackvalue1
Positionfeedbackvalue1
0=notinverted
1=inverted
3 Positionfeedbackvalue2
Positionfeedbackvalue2
0=notinverted
1=inverted
4
15
Reserved
AX5000IDNDescriptions54 Version3.1