Vista de pagina 158
SIDNs
S00348Accelerationfeedforwardgain
Theparametercontainstheaccelerationprecontrol.Thisparameterisactiveinmode"Positioncontrollag
less".Itisusedinselectedapplicationstoadditionallyreducefollowingerrorsduringaccelerationand
deceleration.
Attributes
Name Value
Format udec
Datalength 16
Decimalpoint 4
Minvalue 0.0000
Maxvalue 3.2767
Defaultvalue
Unit %/(rad/s²)
ChangeableinEtherCATstate PreOp,SafeOp,Op
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision from0203
Theaccelerationprecontrolgeneratesasetcurrentthatisaddedtothecontrolvalueofthevelocity
controller(precontrol).Thisparametercanbeusedtoadapttheeffectofaccelerationprecontroltothe
application,bylinearlyscalingtheaccelerationcalculatedbydualdifferentiationofthesetposition.The
accelerationprecontrolcanonlybeusedinconnectionwithcubicinterpolation(P00556),becauseaset
accelerationcanonlybecalculatedfromathirdorderinterpolation.
Explanation:
m=torque
α=angularaccelerationofthemotorshaft
J_tot=totalmomentofinertiaactiveatthemotor
K_T=torqueconstantofthemotor
i_q=torquegeneratingmotorcurrent
Calculationexample:
Parametercalculation:
J
tot
=
kgm
2
K
T
=
Nm/
A
rms
P00092=A
rms
100%=Fullcompensation
AX5000IDNDescriptions 159Version3.1