S00134Mastercontrolword
Theparametercontainsthemastercontrolword.Thisparameteriscyclicallytransferredineach
communicationcyclefromthecontrollertothedrive.Itcontainsthesetoperatingmode(bits8,9,11),Halt
Drive(bit13)andcontrollerenable(bit14).
Attributes
Name Value
Format Binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate No
Cyclictransfer MDT
Deviceparameter No
Relatedtointerfacerevision No
Thecontrollerselectstheoperationmodeviathe3"operationmode"bits8,9,11ofS00134.Ifoperating
mode0isselectedhere,thedriveactivatestheoperatingmodeselectedintheIDN"PrimaryOperationMode"
S00032.If1issentbythecontroller,the"firstsecondarymode"isactivated,seeS00033.
Bitpattern:
Bit Meaning
05 Reserved
6 Realtimecontrolbit1
Realtimecontrolbit1
7 Realtimecontrolbit2
Realtimecontrolbit2
89 Operationmodelow
Operationmodelow
0=mode0or4,dependingonbit11
1=mode1or5,dependingonbit11
2=mode2or6,dependingonbit11
3=mode3or7,dependingonbit11
10 Controlunitsynchronisationbit
ControlunitsynchronisationbitIPOSYNCtoggleswithcycletimetNcycandisusedtosynchronisethe
interpolation.
11 Operationmodehigh
Operationmodehigh
0=mode0to3
1=mode4to7
12 Reserved
13 Halt/restartdrive
HaltDrive/RestartDrive
0=HaltDrive
1=RestartDrive
14 Enabledrive
Enabledrive
0=Drivenotenabled
1=enableDrive
AX5000IDNDescriptions106 Version3.1