SIDNs
S00032Primaryoperationmode
Theparameterselectsthemainoperatingmode.
Attributes
Name Value
Format Binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue 2
Unit
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision from204:additionaloperatingmodes“usingdynamicMDT”
Theoperatingmodes(mainmodeorsecondarymodes1to3)areactivatedviabits9and8inthe
DriveControlWordoftheMDT(S00134).TheDriveStatusWord(S00135)ofthedrivetelegram(AT)
indicatestheactivatedmodeviabits9and8.
Thepositioncontrolledoperatingmodescanonlybeselectedasmainmodewithoutsecondarymode.
Bitpattern:
Value Description
0 nomodeofoperation
nomodeofoperation
1 torquecontrol
Torquecontrol
2 velocontrol
Velocitycontrol
3 posctrlfeedback1
Positioncontrol,feedbacksystem1
4 posctrlfeedback2
Positioncontrol,feedbacksystem2
11 posctrlfeedback1lagless
Positioncontrollagless,feedbacksystem1
12 posctrlfeedback2lagless
Positioncontrollagless,feedbacksystem2
32769 torquecontrolusingdynamicMDT
TorquecontrolusingdynamicMDT
32770 velocontrolusingdynamicMDT
VelocitycontrolusingdynamicMDT
32771 posctrlfeedback1usingdynamicMDT
PositioncontrolusingdynamicMDT,feedbacksystem1
32772 posctrlfeedback2usingdynamicMDT
PositioncontrolusingdynamicMDT,feedbacksystem2
32779 posctrlfeedback1laglessusingdynamicMDT
PositioncontrollaglessusingdynamicMDT,feedbacksystem1
AX5000IDNDescriptions 35Version3.1
Comentarios a estos manuales