Beckhoff AX5000 S-IDN Parameters Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 190
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
SIDNs
S00011Class1diagnostic(C1D)
Theparametercontainserrorgroupsthattriggera"driveshutdown"error.
Attributes
Name Value
Format Binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate No
Cyclictransfer AT
Deviceparameter No
Relatedtointerfacerevision No
Ifanerrorisdiagnosedinthedrive,thisresultsinanerrorresponseandtheerrorbitisset,asdescribed
below.Inaddition,errorbit13issetbyS00135to"1"andisonlyresetto"0"bythedrivewhenthedrive
hasexecutedthecommandS00099andanyerrorshavebeencleared.
Topreciselyidentifytheerror,readtheerrormemory.
Bitpattern:
Bit Meaning
0 Overloadshutdown
Overloadshutdown
0=noerror
1=error
1 Amplifierovertemperatureshutdown
Amplifierovertemperatureshutdown
0=noerror
1=error
2 Motorovertemperatureshutdown
Motorovertemperatureshutdown
0=noerror
1=error
3 Coolingerrorshutdown
Coolingerrorshutdown
0=noerror
1=error
4 Controlvoltageerror
Controlvoltageerror
0=noerror
1=error
5 Feedbackerror
Feedbackerror
0=noerror
1=error
AX5000IDNDescriptions12 Version3.1
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 189 190

Comentarios a estos manuales

Sin comentarios