SIDNs
S00037Additivevelocitycommandvalue
Theparametercontainstheadditivevelocitycommandvalue,whichiscyclicallyaddedtoS00036,ifthe
controllerprovidesthevalue.
Attributes
Name Value
Format dec
Datalength 32
Decimalpoint 0
Minvalue 2147483648
Maxvalue 2147483647
Defaultvalue
Unit rev/(2
30
ms)
ChangeableinEtherCATstate No
Cyclictransfer MDT
Deviceparameter No
Relatedtointerfacerevision No
Theparameterisrelevantforvelocityandpositioncontrolledmodes;forscalingseeS00036.Ifthedriveis
operatedinthepositioninterface,avelocityprecontrolcanbeappliedbythecontrollerhere.
Note
IDNsinvolved
S‐0‐0036 [}43],S‐0‐0044 [}47],S‐0‐0045 [}48],S‐0‐0046 [}49]