SIDNs
S00047Positioncommandvalue
Theparametercontainsthepositioncommandvalue.Inpositioncontrolledmodes,thisparameterisusedto
cyclicallytransferthepositioncommandvaluesfromthecontrollertotheservodrive.Thecycletimeis
specifiedinS00001.
Attributes
Name Value
Format dec
Datalength 32
Decimalpoint 0
Minvalue 2147483648
Maxvalue 2147483647
Defaultvalue
Unit inc
ChangeableinEtherCATstate No
Cyclictransfer MDT
Deviceparameter No
Relatedtointerfacerevision No
Note
IDNsinvolved
S‐0‐0001 [}9],S‐0‐0048 [}51],S‐0‐0076 [}55],S‐0‐0079 [}57],S‐0‐0134 [}106]