SIDNs
S00909DynamicMDTerrorcounter
AteachSync1timethedrivecheckswhethernewvaliddynamicMDTdataarepresent.Ifnot,thiscounteris
incremented.PossiblecausesoferrorarelateEtherCATtelegramsorincorrectlytransferredEtherCAT
telegramswithinvalidchecksums.
Attributes
Name Value
Format UDEC
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate No
Cyclictransfer AT
Deviceparameter No
Relatedtointerfacerevision from204
Thiscountershouldremainstaticatverylowvalues(1or2).Otherwise,thecauseshouldbeanalyzed.
AX5000IDNDescriptions 189Version3.1