Sub-index
0A
h
Brief description
speed
Unit
min
-1
Access
ro
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to read out the momentary speed measurement.
Sub-index
0B
h
Brief description
heat sink temperature
Unit
°C
Access
ro
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to read out the heat sink temperature.
Sub-index
0C
h
Brief description
internal temperature
Unit
°C
Access
ro
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to read the internal temperature of the servo amplifier.
Sub-index
0D
h
Brief description
DC-link (DC-bus) voltage
Unit
V
Access
ro
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to read out the momentary DC-bus voltage.
Sub-index
0E
h
Brief description
regen power
Unit
W
Access
ro
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to read out the momentary regen power.
Sub-index
0F
h
Brief description
I²t loading
Unit
%
Access
ro
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to read out the I²t loading.