Beckhoff AX2000 CANopen communication profile Manual de usuario Pagina 135

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 137
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 134
Index
Sub-
index
DEF Data format Access
PDO
mapp.
Description ASCII Object
607C
h
00
h
4 INTEGER32 rww ý Reference offset
6081
h
00
h
4 UNSIGNED32 rww ý Velocity (Mode: pp)
6083
h
00
h
4 UNSIGNED32 rww ý Acceleration (Mode: pp pv)
6084
h
00
h
4 UNSIGNED32 rww ý Deceleration (Mode: pp pv)
6086
h
00
h
4 INTEGER16 rww ý Type of motion block ramp (motion_profile_type)
6089
h
00
h
4 INTEGER8 rw Notation index: position (not supported)
608A
h
00
h
4 UNSIGNED8 rw Dimension index: position (not supported)
608B
h
00
h
4 INTEGER8 rw Notation index: speed (not supported)
608C
h
00
h
4 UNSIGNED8 rw Dimension index: speed (not supported)
608D
h
00
h
4 INTEGER8 rw Notation index: acceleration (not supported)
608E
h
00
h
4 UNSIGNED8 rw Dimension index: acceleration (not supported)
6093
h
00
h
4 UNSIGNED32 rw Position factor
01
h
4 UNSIGNED32 rww ý Numerator PGEARO
02
h
4 UNSIGNED32 rww ý feed_constant PGEARI
6094
h
00
h
4 UNSIGNED32 rw Velocity factor: encoder
01
h
4 UNSIGNED32 rw Numerator
02
h
4 UNSIGNED32 rw Divisor
6097
h
00
h
4 UNSIGNED32 rw Acceleration factor
01
h
4 UNSIGNED32 rw Divisor
02
h
4 UNSIGNED32 rw Acceleration factor
6098
h
00
h
4 INTEGER8 rww ý Homing type
6099
h
00
h
4 ARRAY ro Homing velocity
01
h
4 INTEGER32 rw ý
Homing velocity
(homing to references switch)
VREF
02
h
4 INTEGER32 ro ý Homing velocity (homing to resolver zero mark) VREF
609A
h
00
h
4 UNSIGNED32 rw ý Homing acceleration
60C2
h
00
h
4 RECORD ro Interpolation time period PTBASE
01
h
4 UNSIGNED8 rw Interpolation time units
02
h
4 INTEGER16 rw Interpolation time index
60FF
h
00
h
4 INTEGER32 rw ý Speed setpoint
6.4 New configuration of AX2000/2500
In AX2000/2500 there are a number of parameters, that can only be integrated into the current firm-
ware program and produce their proper effect for the first time during the initialization phase, when
the amplifier is switched on. As a result, an alteration of one of these parameters means that all
parameters have to be saved, and the amplifier must then be restarted. This can be carried out via
the CAN-bus, by using the following Objects:
1. Write Object 35EB
h
Sub-index 01
h
, value 0, save command
2. Write Object 3632
h
Sub-index 01
h
, value 0, restart amplifier
CANopen for AX2000/2500 135
BECKHOFF 07/2007 Appendix
Vista de pagina 134
1 2 ... 130 131 132 133 134 135 136 137

Comentarios a estos manuales