4.2.1.5 Object 1004h: Number of supported PDOs (DS301)
This Object is only supported to provide compatibility with older versions of the CANopen Standards
DS 301.
The structure of the parameter is as follows:
Sub-index MSB LSB
0 no. of supported RPDOs no. of supported TPDOs
1
no. of supported synchro
-
nous RPDOs
no. of supported synchronous
TPDOs
2
no. of supported asynchro-
nous RPDOs
no. of supported asynchronous
TPDOs
Index
1004
h
Name
no. of supported PDOs
Object code
ARRAY
Data type
UNSIGNED32
Category
O
Sub-indexes:
Sub-index
00
h
Description
no. of supported PDOs
Category
O
Access
ro
PDO mapping
not possible
Value range
00
h
... 1FF01FF
h
Default value
00020002
h
Sub-index
01
h
Description
no. of synchronous PDOs
Category
O
Access
ro
PDO mapping
not possible
Value range
00
h
... 1FF01FF
h
Default value
00
h
Sub-index
02
h
Description
no. of asynchronous PDOs
Category
O
Access
ro
PDO mapping
not possible
Value range
00
h
... 1FF01FF
h
Default value
00020002
h
This only shows the assignment when the AX2000/2500 has started up. Afterwards, the PDOs can
be configured through the communication parameters 1400
h
to 1403
h
, 1800
h
to 1803
h
.
32 CANopen for AX2000/2500
CANopen Drive Profile 07/2007 BECKHOFF