Ethernet Physical Layer
Slave Controller Technology I-27
Table 15: PHY Address configuration matches PHY address settings
Logical Port
Configured address of the PHY
PHY address register value
used by EtherCAT master
PHY address
offset = 0
PHY address
offset = 16
0
0
16
0
1
1
17
1
2
2
18
2
3
3
19
3
none
4-15
20-31
4-15
none
16-31
0-15
16-31
If the actual PHY address settings differ from the PHY address configuration of the ESC, the
EtherCAT master has to use the actual PHY address mapping, i.e., PHY addresses 1-4 for accessing
the PHYs of logical ports 0-3.
Table 16: PHY Address configuration does not match actual PHY address settings
Logical Port
Configured
address of the
PHY
PHY address register value
used by EtherCAT master
0
1
1
1
2
2
2
3
3
3
4
4
none
0, 5-31
0, 5-13
NOTE: PHY address offset is 0 in this case (recommended).