Commissioning
Statusinfo Beckhoff
P24VxxxxUPS
Beckhoff24V
UPScon
nectedto
CP903xISAor
PCIcard
APCBackUPS
Pro280
APCSmart
UPS420
Description
hardware
revision
required!
Battery
replace
service
intervall
has
expired
(bit10is
set).
Implement
edinUPS
Software
version>=
3.0.0.8;
*)Onlyavailableifmodel"SmartSignalingtoanyAPCUPS&TwinCAT"configured!
Requirements
Developmentenviron
ment
Targetsystemtype UPShardware PLClibrariestoinclude
TwinCATv2.8.0,Build>
745TwinCATv2.9.0,
Build>945
PC(i386) BeckhoffP24Vxxxx
USV;
IntegratedBeckhoff
IndustrialPC24V
UPSconnectedto
CP903xISAorPCI
card;
WithBeckhoff
IndustrialPC's
deliveredAPCUPS
modelssupporting
smartprotocoland
configuredwith
WindowsUPS
Service;
TcIoFunctions.Lib
(Standard.Lib;
TcBase.Lib;
TcSystem.Lib;
TcUtilities.Libareincluded
automatically)
5.3.3 TYPEE_BatteryStatus
TYPEE_BatteryStatus:
(
BatteryUnknownStatus,(*Thebatterystatusisunknown.*)
BatteryOk,(*ThebatteriesareOK.*)
BatteryReplace(*Thebatteriesneedtobereplaced.*)
END_TYPE