Beckhoff CX2100­09x4 Manual de usuario Pagina 53

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 87
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 52
Commissioning
Setting/command Area Defaultvalue Description UPSsoft
warever
sion
Activateallnotifications Deactivated
oractivated
Deactivated
(checkboxnot
checked)
Thisoptioncanbeusedtoinstruct
theoperatingsystemtosend
messagestotheuserincaseof
Powerfailure.
Secondsbetweenthepower
failureandthefirstnotification
0..120[s] 5 Thedelayafterwhichthefirst
"powerfail"messagewillbesent.
v2.0.0.15
Secondsbetweenfurther
powerfailurenotifications
0..300[s] 20 Thetimethatelapsesbefore
additionalmessagesaresenttothe
user.
v2.0.0.15
Criticalalarm Thealarmistriggeredoncethe
batteryvoltagehasfallentoa
certainleveloroncebattery
operationhasexceededacertain
timelimit.
Minutesremainingforbattery
operationbeforecriticalalarm:
0..720[min] 2 Ifyouhaveselectedthisoption,the
UPSservicewillinitiatethecritical
alarmafterthesettimeandwill
shutdownthePC.Thecritical
alarmmay,however,beissued
earlierifthebatterycapacityis
exhausted.Ifthevalueissetto0,
thePCwillbeshutdown
immediatelyintheeventofapower
failure,andtheOSshutdowncan
nolongerbestopped.
Onalarm,executethe
followingprogram(task)*
Deactivated
oractivated
Deactivated
(checkboxnot
checked)
Withthisoptionanapplicationcan
beexecutedonalarm,butbefore
theactualshutdown(Task
Schedulershutdowntask).The
TaskSchedulertasksfoundare
displayedinthelistbelowafter
selectingthisoption.Subsequently,
ataskmustbeselectedfromthe
list.Thedefaulttaskwiththename
"UPSSystemShutdownProgram"
isautomaticallyselectedifitexists
andifnoothertaskhasbeen
configuredbeforehand.
Combobox(tasklist) TaskSched
ulertasks
"UPSSystem
Shutdown
Program"
Pleasedonotforgettosettheuser
nameandhispasswordduringthe
configurationoftheshutdowntask.
Theshutdowntaskismanagedby
theWindowsTaskSchedulerand
canonlybeexecutedinacertain
usercontext.Theconfigureduser
mayrequirespecialaccessrights
tothesystem,drives,etc.Ifthe
configuredusername/password
correspondstotheloggedinuser,
theshutdowntaskisinteractively
executed(visibleinthe
foreground)."NTAUTHORITY
\SYSTEM"canbealsoenteredas
thesystemuseraccount(system
account,apasswordisnot
necessaryinthiscase).The
systemuseraccounthasfull
accesstothelocalcomputer,but
v3.0.0.10
CX210009x4 53Version1.1
Vista de pagina 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 86 87

Comentarios a estos manuales

Sin comentarios