Ethernet
Fieldbus-Connectivity
Interface AX2000
-B110 -B200 -B310 on-board -B520 -B750 on-board -B900
Technical data
AX2003 AX2006 AX2010 AX2020 AX2040 AX2070
Rated output current 3 A 6 A 10 A 20 A 40 A 70 A/80 A
Rated supply voltage 3x (230 … 480) V 3x (230 … 480) V 3x (230 … 480) V 3x (230 … 480) V 3x (230 … 480) V 3x (230 … 480) V
AC ±10%, AC ±10%, AC ±10%, AC ±10%, AC ±10%, AC ±10%,
50 … 60 Hz 50 … 60 Hz 50 … 60 Hz 50 … 60 Hz 50 … 60 Hz 50 … 60 Hz
Rated installed load 2 kVA 4.2 kVA 7 kVA 14 kVA 30 kVA 50 kVA
for S1 operation
Rated intermediate
(310 – 675) V DC (310 – 675) V DC (310 – 675) V DC (310 – 675) V DC (310 – 675) V DC (310 – 675) V DC
circuit DC voltage
Rated output current
3 A
rms
6 A
rms
10 A
rms
20 A
rms
40 A
rms
70 A
rms
/80 A
rms
(rms value 3 %)
Peak output current
6 A
rms
12 A
rms
20 A
rms
40 A
rms
80 A
rms
140 A
rms
/160 A
rms
(max. approx. 5 s 3 %)
Continuous output of
80 W 200 W 200 W 200 W – –
regen circuit (RBint)
Continuous output of
250 W 750 W 750 W 750 W 6 kW 6 kW
regen circuit (RBext) max.
Weight
4 kg 4 kg 5 kg 7.5 kg 19.5 kg 21 kg
Height 275 mm 275 mm 275 mm 275 mm 495 mm 495 mm
without connectors
Width
70 mm 70 mm 70 mm 120 mm 250 mm 250 mm
Depth 265 mm 265 mm 265 mm 265 mm 300 mm 300 mm
without connectors
We reserve the right to make technical changes.BECKHOFF New Automation Technology
Drive Technology
70
AX20xx | Digital Compact Servo Drives