Beckhoff FC520x Manual de usuario Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 51
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
Eiserstraße 5 / D-33415 Verl / Telefon 05246/963-0 / Telefax 05246/963-149
FC520x / CX1500-x520 42
BECKHOFF FC520x / CX1500-x520
5.2 Device Diagnostics
Note: It is mandatory and recommended to take all the diag-
nostic Inputs of the DeviceNet Device into account.
5.2.1 Common Inputs
cycleCounter
: DeviceNet-FW increments this counter once after each cycle
error
: indicates the number of boxes with a BoxState unequal zero
actualCycleTime
: reserved for future use
DiagFlag
: Shows whether the diagnostics information on the card has changed. This can be read off
using ADS Read. For that purpose, specify the net ID of the FC520x / CX1500-x520, the port number 200
and the IndexGroup 0xF100. The IndexOffset and the length then relate to the diagnostic data.
CycleFailedCounter
: This counter increments each time when at the beginning of theTwinCAT-Cycle
the last Bus-Cycle was not finished
Vista de pagina 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 49 50 51

Comentarios a estos manuales

Sin comentarios