Eiserstraße 5 / D-33415 Verl / Telefon 05246/963-0 / Telefax 05246/963-149
Software description of functions 22
Beckhoff Lightbus - PC interface card C1220
Initialisation of string communication
String communication is initialised via the handshake channel with function
0x14.
ArgumentChannel Length Function
0 1 2 3
Request
0x0A 0x14
Init
StringComm.
(0x01)
CDL no.
string Trns
CDL no.
string receive
Max. string
length
Request
0x03 0x14
Deinit
StringComm.
(0x00)
Deactivation of string communication also
deactivates all the string slaves.
Reply
0x03 0x14 0x00 No error.
0x01 Wrong CDL number for string transmit CDL.
0x02
String transmit CDL already occupied.
0x03 Wrong CDL number for string receive CDL.
0x04
String receive CDL already occupied.
0x05
Wrong transmit string base address.
0x06
Wrong receive string base address.
Argument
4 5 6 7
Offset string transmit buffer Offset string receive buffer
Deactivation of string communication also deactivates all the string
slaves.
No error.
Wrong CDL number for string transmit CDL.
String transmit CDL already occupied.
Wrong CDL number for string receive CDL.
String receive CDL already occupied.
Wrong transmit string base address.
Continuation of the table
Wrong receive string base address.