C1300 VME to II/O Interface Unit Beckhoff II/O-System
Date : 18.12.95 Version : 2.01 Page 23 of 44
Funktion 08
h
: continuous transmission
This function only controls the "cycle"-LED on the modules.This way it is
possible to find out how many modules are still connected to the transmission
output of the C1300. This function is only supposed to be activated, if there is no
satisfying result from the function 0ah ( fraction test ).The only way for the
software to stop continuous transmission is a reset .
channel length function argument
0
argument
1
argument
2
comment
call
02 08
response
03 08 01
constant transmission can be
stopped by reset
While continuous transmission is working the functions 05h to 07h and 0ah are
inhibited.