Installation Instructions
Power Supply Connection
Supplied mains power unit The Industrial PC is fitted with a 100-240 V, 50-60 Hz full range power
supply unit (with the option of an uninterruptible power supply, UPS).
Current carrying capacity
of the 100-240 V power
supply unit
Output voltages from
the 100-240 V power
supply unit
Current loading
maximum
+3,3 V
16 A
+5 V stand by
2 A
+5 V
25 A
-5 V
0,3 A
+12 V
13 A
-12 V
0,8 A
Mains Socket
A mains socket is located at the rear of the PC housing in order to connect
the power supply.
Socket at the PC housing
Power supply cords
Power cords Europe In the area Europe you use the provided cable with inlet connector for non-
heating apparatus to connect the Industrial-PC to the power supply.
Power cords USA / Canada In the area USA / Canada the power supply cable must show the following
specifications according to the supply voltage:
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 125 V,
10 A, Type SJT or Type SVT; one end terminates in NEMA 5-15P/-20P
grounding-type attachment plug, other end in appliance coupler
or
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250 V,
10 A, Type SJT or Type SVT; one end terminates in NEMA 6-15P/-20P
grounding-type attachment plug, other end in appliance coupler.